Sichuan, China
Business Type:
Trading Company
Business Range:
Furniture, Health & Medicine, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001, ISO 20000, GMP, ISO 13485
Main Markets:
Europe, Southeast Asia/ Mideast, Africa
OEM/ODM Service
Sample Available

Patient Monitor, Multi-Parameter Patient Monitor, Monitor manufacturer / supplier in China, offering 12 Inch Hospital ICU Ccu Multi-Parameter Patient Monitor, Ce Approved Ysd2100-06 Trolley Digital Ultrasound Equipment, Full Digital Laptop Veterinary Ultrasound Scanner CE ISO Approved Ysd3006-Vet and so on.

Gold Member Since 2016
Audited Supplier

12 Inch Hospital ICU Ccu Multi-Parameter Patient Monitor

Get Latest Price
Purchase Qty. / Reference FOB Price
1-999 Pieces US $600
1,000+ Pieces US $1
Port: Chengdu, China
Production Capacity: 10000units Per Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient/Fetal/Maternal Monitor
Certification: CE, FDA, EEC, MSDS, ISO13485
Group: Middle-aged and Old
Medical Device Regulatory Type: Type 2
Medical Devices Reg./Record No.: 20142211159

You Might Also Like


Basic Info

Model NO.: YSD18
Display: 12.1" Color TFT Touch-Screen Display
Manufacture: Yes
OEM: Acceptable
Touch Screen: Yes
Color: White
Warranty: 12 Months
Export Markets: The Whole World
Wire or Wireless Network: Support
Power: Plug-in Rechargeable Battery, AC/DC Available
N.W: 1.5kg
Trademark: YSD
Transport Package: Carton
Specification: 210mm*185mm*100mm
Origin: Chengdu
HS Code: 90181930

Product Description

Product  Features

Δ. 12.1" color TFT touch screen
Δ. Windows style, Multi-channel display
Δ. Big font interface
Δ. ST and arrhythmia analysis
Δ. Drug dose calculation and titration table
Δ. OxyCRG dynamic view display
Δ. Respiration monitoring with apnea alarms
Δ. Alarm review, arrhythmia review
Δ. Patient info. Input
Δ. Anti-defibrillation design
Δ. NIBP over pressure protection
Δ. Plug-in rechargeable battery, AC/DC available.
Δ. Supporting wire or wireless network.

Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.


Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology
Nellcor(TM)  OxiMax(TM) delivers excellent performance,
even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.


Collaborate with Respironics, Plug and Play EtCO2 monitoring.
CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small, durable and lightweight mainstream sensor provides accurate
and reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor for monitoting non-intubated patient.
Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal patients.

Multi Mounting Solutions


Lead Mode                          5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection                     I, II, III, avR, avL, avF, V
Wave form                          2 ch
Lead mode                          3 Leads ( R, L, F or RA, LA, LL)
Lead selection                     I, II, III,
Wavef orm                          1 ch
Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range                 Adult    15 ~ 300 bpm
                                   Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                         1 bpm
Sensitivity                        > 200 (uVp-p)
Differential Input Impedance       > 5 MΩ

CMRR                    Monitor > 105 dB
                                   Operation > 105 dB
                                   Diagnosis > 85 dB
Electrode offset potential         ±300mV
Leakage Current                    < 10 uA
Baseline Recovery                  < 3 S After Defi.
ECG Signal Range                   ±8 m V ( Vp-p )

Bandwidth                           Surgery    1 ~ 20 Hz
                                    Monitor     0.5 ~ 40 Hz
                                    Diagnostic  0.05 ~ 130 Hz
Calibration Signal                  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV



Method                            Impedance between R-F(RA-LL)
Differential Input Impedance         > 2.5 MΩ
Measuring Impedance Range        0.3~3 Ω
Base line Impedance Range         200~4 KΩ
Bandwidth                          0.1~2.5Hz
Resp. Rate                         Measuring and Alarm Range
                                    Adult 0 ~ 120 Brpm
                                    Neo/Ped 0 ~ 150 Brpm
                                    Resolution 1 Brpm
                                    Accuracy ±2 Brpm

Apnea Alarm                        10 ~ 40 S


Method                            Oscillometric
Mode                              Manual, Auto, STAT                
Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range           40 ~ 240 bpm
Alarm Type                  SYS, DIA, MEAN

Measuring and alarm range        Adult Mode
                                    SYS 40 ~ 270 mmHg
                                    DIA 10 ~ 215 mmHg
                                    MEAN 20 ~ 235 mmHg
                                Pediatric Mode
                                    SYS 40 ~ 200 mmHg
                                    DIA 10 ~ 150 mmHg
                                    MEAN 20 ~ 165 mmHg
                                Neonatal Mode
                                    SYS 40 ~ 135 mmHg
                                    DIA 10 ~ 100 mmHg
                                    MEAN 20 ~ 110 mmHg
Resolution                      1mmHg

Accuracy                        Maximum Mean error ±5mmHg
                                Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg
                                 Pediatric Mode 240±3 mmHg
                                 Neonatal Mode 147±3 mmHg

Measuring Range                  0 ~ 100 %
Alarm Range                      0 ~ 100 %
Resolution                       1 %
Accuracy                         70% ~ 100%  2 %
                                 0%  ~  69% unspecified
Actualization intervalabout      1 Sec.
Alarm Delay                      10 Sec.
Pulse Rate                       Measuring and Alarm Range 20~300 bpm
                                 Resolution       1bpm
                                 Accuracy ±3bpm


Channe                          2
Measuring and Alarm Range 0 ~ 50 ºC
Resolution                      0.1 ºC
Accuracy                 ±0.2 ºC
Actualization intervalabout     1 Sec.
Average Time Constant           < 10 Sec.


Label                           ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range       ART 0 ~ 300 mmHg
                                PA -6 ~ 120 mmHg
                                CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                P1 / P2-10 ~ 300 mmHg

Press Sensor                    Sensitivity 5  uV/V/mmHg
                                Impedance 300-3000Ω

Resolution                      1 mmHg
Accuracy                        ±2% or 1mmHg which is greater
Actualization interval         about 1 secretary

Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

Technical data sheet


Auto measure time:Adjustable
Measurement range:10-270mmHg



Lead mode: 3-lead or 5-lead
Lead selection: I;II;III,avR;avF;V
Heart rate range: Adult:15-300bpm;Pediatric/Neonatal:15-  300bpm
ECG waveform: 2 channals
Accuracy: ±1 bpm or ±1%,which is greater
S-T segment detection;measurement range: 2.0mv~2.0mv
Alarm:Yes,audible and  visual alarm,alarm events review


Measurement range:0-100%
Auto measure time:Adjustable

Pulse Rate

Accuracy: ±3bpm


Method:RA-LL impedance
Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm
Apnca alarm:Yes


Accuracy: ± 0.10

Main unit

ECG cable
Spo2 probe
TEM Probe
Adult cuff
Power cable
User manual
ECG Electrodes

Warranty Period:
Delivery timeWithin 7 working days upon receipt the payment
Terms of paymentT/T,L/C,  western union
Shipping termsBy sea, by air or by express


Send your message to this supplier

avatar Miss Christina Lee

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now