Sichuan, China
Business Type:
Trading Company
Business Range:
Furniture, Health & Medicine, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001, ISO 20000, GMP, ISO 13485
Main Markets:
Europe, Southeast Asia/ Mideast, Africa
OEM/ODM Service
Sample Available

Patient Monitor, Multi-Parameter Patient Monitor, Touch Screen Monitor manufacturer / supplier in China, offering Ce Approved Hospital ICU 12.1 Inch Multi-Parameter Patient Monitor, Ce Approved Ysd2100-06 Trolley Digital Ultrasound Equipment, Full Digital Laptop Veterinary Ultrasound Scanner CE ISO Approved Ysd3006-Vet and so on.

Gold Member Since 2016
Audited Supplier

Ce Approved Hospital ICU 12.1 Inch Multi-Parameter Patient Monitor

Get Latest Price
Purchase Qty. / Reference FOB Price
1-999 Pieces US $600
1,000+ Pieces US $1
Port: Chengdu, China
Production Capacity: 10000units Per Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient/Fetal/Maternal Monitor
Certification: CE, FDA, EEC, MSDS, ISO13485
Group: Middle-aged and Old
Medical Device Regulatory Type: Type 2
Medical Devices Reg./Record No.: 20142211159

You Might Also Like


Basic Info

Model NO.: YSD18C
Standard Parameters: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temp
Type.: Patient/Fetal/Maternal Monitor
Optional: Nellcor SpO2, Etco 2IBP, Thermal Recorder
Display: 12.1" Color TFT Touch-Screen Display
Color: White
Warranty: 12 Months
Export Markets: The Whole World
Touch Screen: Yes
Wire or Wireless Network: Support
N.W: 1.5kg
Trademark: YSD
Transport Package: Carton
Specification: 210mm*185mm*100mm
Origin: Chengdu
HS Code: 90181930

Product Description

Product  Features

Δ. 12.1" color TFT touch screen
Δ. Windows style, Multi-channel display
Δ. Big font interface
Δ. ST and arrhythmia analysis
Δ. Drug dose calculation and titration table
Δ. OxyCRG dynamic view display
Δ. Respiration monitoring with apnea alarms
Δ. Alarm review, arrhythmia review
Δ. Patient info. Input
Δ. Anti-defibrillation design
Δ. NIBP over pressure protection
Δ. Plug-in rechargeable battery, AC/DC available.
Δ. Supporting wire or wireless network.

Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.


Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology
Nellcor(TM)  OxiMax(TM) delivers excellent performance,
even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.


Collaborate with Respironics, Plug and Play EtCO2 monitoring.
CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small, durable and lightweight mainstream sensor provides accurate
and reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor for monitoting non-intubated patient.
Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal patients.

Multi Mounting Solutions


Lead Mode                        5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
Lead selection                     I, II, III, avR, avL, avF, V
Wave form                        2 ch
Lead mode                        3 Leads ( R, L, F or RA, LA, LL)
Lead selection                     I, II, III,
Wavef orm                          1 ch
Gain                               2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto

HR and Alarm Range                 Adult    15 ~ 300 bpm
                                   Neo/Ped    15 ~ 350 bpm
Accuracy                           ±1% or±1bpm, which is greater
Resolution                         1 bpm
Sensitivity                        > 200 (uVp-p)
Differential Input Impedance       > 5 MΩ

CMRR                    Monitor > 105 dB
                                   Operation > 105 dB
                                   Diagnosis > 85 dB
Electrode offset potential         ±300mV
Leakage Current                    < 10 uA
Baseline Recovery                  < 3 S After Defi.
ECG Signal Range                   ±8 m V ( Vp-p )

Bandwidth                           Surgery    1 ~ 20 Hz
                                    Monitor     0.5 ~ 40 Hz
                                    Diagnostic  0.05 ~ 130 Hz
Calibration Signal                  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range         Measure and Alarm -2.0 ~ +2.0 mV

                                          PNP, PNC,Alarm Available,Review Available

MethodImpedance between R-F(RA-LL)
Differential Input Impedance  I > 2.5 MΩ
Measuring Impedance Range  I 0.3~3 Ω
Base line Impedance Range 200~4 KΩ
Bandwidth  I 0.1~2.5Hz
Resp. Rate Measuring and Alarm RangeAdult 0 ~ 120  Brpm Neo/Ped 0 ~ 150 Brpm Resolution 1 Brpm Accuracy ±2 Brpm
Apnea Alarm  10 ~ 40 S
Method                            Oscillometric
Mode                              Manual, Auto, STAT                     
Measuring Interval in AUTO Mode   1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode     5 Min
Pulse Rate Range           40 ~ 240 bpm
Alarm Type                  SYS, DIA, MEAN

Measuring and alarm range        Adult Mode
                                    SYS 40 ~ 270 mmHg
                                    DIA 10 ~ 215 mmHg
                                    MEAN 20 ~ 235 mmHg
                                Pediatric Mode
                                    SYS 40 ~ 200 mmHg
                                    DIA 10 ~ 150 mmHg
                                    MEAN 20 ~ 165 mmHg
                                Neonatal Mode
                                    SYS 40 ~ 135 mmHg
                                    DIA 10 ~ 100 mmHg
                                    MEAN 20 ~ 110 mmHg
Resolution                      1mmHg

Accuracy                        Maximum Mean error ±5mmHg
                                Maximum Standard deviation ±8mmHg
Overpressure Protection          Adult Mode 297±3 mmHg
                                 Pediatric Mode 240±3 mmHg
                                 Neonatal Mode 147±3 mmHg

Measuring Range                  0 ~ 100 %
Alarm Range                      0 ~ 100 %
Resolution                       1 %
Accuracy                         70% ~ 100%  2 %
                                 0%  ~  69% unspecified
Actualization intervalabout      1 Sec.
Alarm Delay                      10 Sec.
Pulse Rate                       Measuring and Alarm Range 20~300 bpm
                                 Resolution       1bpm
                                 Accuracy ±3bpm


Channe                          2
Measuring and Alarm Range 0 ~ 50 ºC
Resolution                      0.1 ºC
Accuracy                 ±0.2 ºC
Actualization intervalabout     1 Sec.
Average Time Constant           < 10 Sec.

LabelART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range ART 0 ~ 300 mmHg PA -6 ~ 120 mm  Hg CVP/RAP/LAP/ICP-10 ~ 40 mm    Hg P1 / P2-10 ~ 300 mmHg
Press Sensor Sensitivity 5 uV/V/mmHg Impedance 300-3000Ω
Resolution 1 mmHg
Accuracy ±2% or 1mmHg which is greater
Actualization interval about 1 secretary
Standard ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

Why choose us:
we got production and business certification from Chengdu food and Drug Administration
we got business license from Chengdu City Administration of industry and commerce
we got products certificate of registration and have checked in the website of SFDA
we have accepted the onsite check from SFDA every quarter
we finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;

Send your message to this supplier

avatar Miss Christina Lee

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now