Sichuan, China
Business Type:
Trading Company
Business Range:
Furniture, Health & Medicine, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001, ISO 20000, GMP, ISO 13485
Main Markets:
Europe, Southeast Asia/ Mideast, Africa
OEM/ODM Service
Sample Available

Patient Monitor, Portable Patient Monitor, Multi-Parameter Patient Monitor manufacturer / supplier in China, offering Hospital Device 12.1 Inch Multi-Parameter Patient Monitor, Ysd1300c Multi-Parameter High Qualified Medical Diagnositic Machine Ultrasound, Ce Certified Medical Diagnostic Equipment Ultrasound Scanner and so on.

Gold Member Since 2016
Audited Supplier

Hospital Device 12.1 Inch Multi-Parameter Patient Monitor

Get Latest Price
Purchase Qty. / Reference FOB Price
1-999 Pieces US $700
1,000+ Pieces US $1
Port: Chengdu, China
Production Capacity: 10000units Per Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram
Classification: Physiological Functions of Diagnosis and Monitoring Equipment
Type: Patient/Fetal/Maternal Monitor
Certification: CE, FDA, EEC, MSDS, ISO13485
Group: Middle-aged and Old
Medical Device Regulatory Type: Type 2
Medical Devices Reg./Record No.: 20142211159

You Might Also Like

Loading...

Basic Info

Model NO.: YSD16S
Display: 12.1" Color TFT Display
Color: White
Warranty: 12 Months
Export Markets: The Whole World
N.W: 3.4kg
G.W.: 7 Kg
Delivery Time: 5~7 Working Days After Receiving Full Payment
Way of Delivery: Express, Air, Ship
Payment: T/T , Western Union
ECG: 6 Channel
Trademark: YSD
Transport Package: Carton
Specification: 310mm*290mm*150mm
Origin: Chengdu, China
HS Code: 90181930

Product Description

YSD16S Multi-parameter Patient Monitor

Product Descripion:

The YSD16S patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments. An optional Nellcor /Masimo SpO2 module enable accurate measurement in NICU.


Hospital Device 12.1 Inch Multi-Parameter Patient Monitor


Main Features 

Body

  • 12.1 inch high-brightness TFT LED
  • Support display maximum 8 waveforms
  • Support 6 channel ECG waveform display simultaneously 
  • Optional touch screen
Stroage
  • Support storage of 168 hours trend table and graph review
  • 100 minutes waveform review
  • 500 groups NIBP review
  • 100 hours of parameter alarm events review and associated parameters
Printer
  • Built-in high-speed 50mm thermal printer
        (Brand: SEIKO, Japan)
 
Central System
  • Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
Alarm
  • Three-level acousto-optic alarm
  • Sensor-off alarm
  • Paper out alarm
  • Support alarm review
  • Support alarm pause
Operating System
  • Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph, NIBP review and full leads ECG interface.
  • NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
  • 13 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
  • Drug calculation and titration table
  • Support multi-language display
  • Support online software upgrading by net
Alarm
  • Three-level acousto-optic alarm
  • Sensor-off alarm
  • Paper out alarm
  • Support alarm review
  • Support alarm pause
Hospital Device 12.1 Inch Multi-Parameter Patient Monitor

Interface
Transducer socket
  • ECG
  • SPO2
  • NIBP  
  • IBP 1 / IBP 2
  • TEMP 1
  • TEMP 2 / Mainstream EtCO2 / AG (multi-gas)
  • Sidestream EtCO2
LAN / Central monitor system interface
  • The LAN port is for connecting the monitor to a central monitor system network.
Input device interface
  • This optional interface provides an USB ports to enable the monitor to be connected to off-the-shelf input devices:
  • Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
  • Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
  • Knob (Standard)
  • Touch screen (optional)
 
Specifications

Dimension and Weight
  • Dimension: 310mm*290mm*150mm
  • Weight: 3.4kg(excluding accessories)
Power Supply
  • Voltage: AC100~240V, 50/60HZ, Power≤60W 
Display
  • 12.1" color TFT LED  
  • Resolution: 800*600 pixels
Battery (Pluggable)
  • Type: Rechargeable lithium battery 14.8V/2200mAh
  • Charge Cycle: ≥500 times
  • Working time: 2 hours (optional larger battery for 4-5 hours)
Recorder (Option)
  • Method: Thermal printer
  • Paper width: 50 mm (1.97 in)
  • Printing speed: 12.5/ 25/ 50 mm/s
  • Trace: Max. 3 tracks
  • Recording way: Real-time Recording, Review Printing,  
Periodic Recording, Alarm Recording

Alarm
  • Level: Low, medium and high
  • Indication: Auditory and visual
  • Alarm volume adjustable
  • Alarm pause time: 1min, 2min
  • Parameter alarm type: Latch/ Unlatch
Input Device
  • Touch screen (option)
  • Knob (Standard)
  • Keypad input (Standard)
  • Mouse/ Keyboard input (option)
System Output & Extensible Interface
  • Ethernet Network: 1 standard RJ45 socket
  • USB Port: 1
  • Video Output: 1 HDMI port (option)
Operating Environment
  • Temperature:  5 ~ 40 ºC
  • Humidity:  15% ~ 80% (non-condensing)
  • Atmosphere pressure:  86 KPa ~ 110 KPa
Transportation and Storage Environment
  • Temperature:  -20~50 ºC
  • Humidity:  10%~90%  (non-condensing)
  • Atmosphere pressure:  86 KPa ~ 110 KPa
Safety
  • IEC60601-1 Approved, CE marking according to MDD93/42/EEC
  • With reference to RoHS Directive 2011/65/EU recasting
Trend & Reviewing
  • Trend: 2160 hours
  • ARR events: 128 groups of ARR events and associated waveform
  • NIBP measurement reviewing: 2000 groups
  • Waveform review: 2 hours
  • Alarm event: 2000 groups of parameter alarms events and associated parameter 

ECG
    Lead mode 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
    Protection Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
    Gain 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
    Sweep speed 12.5 mm/s, 25 mm/s, 50 mm/s
    ECG signal range ±12 mV (Gain × 0.25)
    Accuracy ±1bpm/ ±1%, whichever is greater
    Resolution 1 bpm Leakage Current < 10 μA
    Baseline Recovery ≤ 3s after defibrillation (Monitor mode)≤ 1s after defibrillation (Surgery mode)
    Bandwidth Surgery 1 ~ 25 Hz
    Monitor 0.5 ~ 40 Hz
    Diagnostic 0.05 ~ 120 Hz
    Indication of Electrode Separation Every electrode (exclusive of RL

    Heart Rate
    • Measure range:
    Adult: 0bpm; 10 ~ 300 bpm
    Neo/Ped: 0bpm; 10 ~ 350 bpm
    • Resolution: 1 bpm
    • Accuracy: ± 1% or ± 1bpm, whichever is greater
    ST Measurement
    • Range: -2.0 ~ +2.0 mV
    • Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
    • Other range: unspecified
    • Resolution: 0.01mV 
    Respiration
    • Method: Impedance between RA-LL, RA-LA
    • Gain: ×0.25, ×0.50, ×1, ×2, ×4
    • Respiration Rate: 0bpm, 6 ~ 150 BrPM
    • Sweep speed:  6.25 mm/s, 12.5 mm/s, 25mm/s
    • Resolution: 1 BrPM
    • Accuracy: ±2 bpm or ±2%, whichever is greater
    • Apnea Alarm: 10 ~ 60 s 
    NIBP
    • Method: Oscillometric
    • Measure mode: Manual, Auto, STAT
    • Measure Interval in AUTO Mode 1~480 min
    • STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
    • Measure and Alarm Range:
              Adult: SYS:30 ~ 270 mmHg 
              Pediatric: SYS:40 ~ 235 mmHg
    • Static pressure accuracy: ±3mmHg
    • Resolution: 1mmHg
    • Accuracy: Maximum Mean error ±5mmHg          
    Maximum Standard deviation ≤8mmHg
    • Over pressure Protection: Dual protection via software & hardware  
    Temperature
    • Technique: Thermistor probe (2.25K)
    • Channel:  Dual-channel, provide T1; T2; ΔT
    • Measuring and Alarm Range:
    0.0 ºC~ 50 ºC (32ºF~ 122ºF)
    • Unit: Celsius (ºC), Fahrenheit ( ºF)
    • Resolution: 0.1ºCor 1ºF
    • Accuracy: ±0.1ºC(exclusive probe)  
    SpO2 (Digital Technic)
    • Measurement Range: 0 ~ 100 %
    • Resolution: 1 %
    • Accuracy:  ±2% (70% ~ 100%)
                ±3 % (35% ~ 69%) Unspecified (0 ~ 34%)
    • Support Pitch tone and multi-level volume    
    Pulse Rate
    • Measuring and Alarm Range: 25~250bpm
    • Accuracy: ±1% or ±1 bpm, whichever is greater
    • Resolution: 1bpm 
    Nellcor-SpO2 (Option)
    • Measurement Range: 0 ~ 100 %
    • Resolution: 1 %
    • Accuracy:   70% ~ 100%, ±2 % (adult)
                 70% ~ 100%, ±3 % (Neonate)
                 70% ~ 100%, ±2 % (Low Perfusion)
                 0% ~ 69%, unspecified
     
    Pulse Rate
    • Measurement range: 20 ~ 300 bpm
    • Resolution: 1bpm
    • Accuracy: ±3 bpm (20 ~ 250 bpm) unspecified (251~300 bpm)
     
    Masimo SpO2 (Option)
    • - Measurement Range: 0 ~ 100 %
    • - Resolution: 1 %
    • Accuracy: 
                70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
                70% ~ 100%, ±3 % (neonate, non-motion conditions)
                70% ~ 100%, ±3 % (motion conditions)
                0% ~ 69% unspecified
    Pulse Rate
    • Measurement range: 25 ~ 240 bpm
    • Resolution: 1bpm
    • Accuracy: ±3 bpm (non-motion condition)
     EtCO2 (Mainstream/ Sidestream) (Option)
    • Measure method:  Non-dispersive infrared (NDIR)
    • Measure Range:  0 ~19.7% (0 ~ 150 mmHg)
                     0 ~ 20 kPa
    • Resolution: 0.1 mmHg
    • CO2 Accuracy: 
              0 ~ 40 mmHg, ±2 mmHg
              41 ~ 70 mmHg, ±5% of reading
              71 ~ 100 mmHg, ±8% of reading
              101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 25ºC)
    • Respiratory Rate:  Range: 3 ~150 BrPM
    Accuracy: ±1 bpm
     
    EtCO2 (Micro-stream) (Option)
    • Measure method:  Non-dispersive infrared (NDIR)
    • Measure Range:  0 ~19.7% (0 ~150 mmHg)
                     0 ~ 20 kPa
    • Sample Rate: 50 mL/min ±10mL/min
    • Resolution:  0.1 mmHg (0 ~ 50 mmHg) 0.25 mmHg (50 ~ 114 mmHg)
    • CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg
                    41 ~ 70 mmHg, ±5% of reading
                    71 ~ 100 mmHg, ±8% of reading
                   101~ 150 mmHg, ±10% of reading at 760 mmHg, ambient temperature of 35ºC)
    • Respiratory Rate: Range: 3 ~120 BrPM  Accuracy: ±1 bpm
       
    Depth of Anesthesia (CSI) (Option)
    • EEG sensitivity:  ± 400μV
    • Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz
    • CMRR: > 140 dB
    • Input impedance: > 50 Mohm
    • Sample rate: 2000 samples/sec, (14 bits equivalent)
    • BS%: 0-100, filter 1-42 Hz, 1 sec. display update
    • EMG: 0-100 Logarithmic. Filter 75-85 Hz, 1 sec. update
    • Alarms: High / Low with user selectable limit
    • Artifact rejection: Automatic
    • Sensor impedance range: 0 - 10 kOhm / measurement current 0.01 μA
    Multi-gas/O2 (Anesthetic Gas) (Option)
    • Method: Infrared absorption
    • Gas sorts: CO2, N2O, Des, Iso, Enf, Sevo, Hal, O2 (Optional paramagnetic sensor)
    • Calibration: Room air calibration performed automatically when changing airway. Airway adapt (< 5 sec)
    • Measurement range:
              CO2: 0~25%, N2O : 0~100%
              O2: 0~100%,  Enf, Iso, Hal: 0~25%, Sevo, Des: 0~25%
    • Data output: Fi and ET values
    • Respiration rate: 0~ 150 BrPM
    • Other: Up to 5 waveforms displayed
              Agent mixture detection
              MAC value displayed
     
    IBP (Option)
    • Max Channel: 2
    • Measurement way: Thermal resistance way
    • Press Sensor:  Sensitivity   5 uV/V/mmHg, ±2%
                  Impedance   300 to 3000Ω
    • Resolution: 1 mmHg
    • Unit: mmKg, kPa, cmH2O
    • Transducer sites: 
    Arterial Pressure (ART)
    Pulmonary Arterial (PA)
    Left Arterial (LAP)
    Right Arterial (RAP)
    Central Venous Pressure (CVP)
    Intracranial Pressure (ICP)
    P1/ P2
    • Measuring and alarm range:
    ART: 0 ~ +350mmHg
    CVP/ RAP/ LAP/ ICP: -10 ~ +40 mmHg
    P1/ P2: -50 ~ +350mmHg
    • Accuracy:  Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer) ±4mmHg or ±4%, whichever is greater (inclusive of transducer)
    Hospital Device 12.1 Inch Multi-Parameter Patient Monitor


    Hospital Device 12.1 Inch Multi-Parameter Patient Monitor

    Why choose us:

    We got production and business certification from Chengdu food and Drug Administration
    We got business license from Chengdu City Administration of industry and commerce
    We got products certificate of registration and have checked in the website of SFDA
    We have accepted the onsite check from SFDA every quarter
    We finished the training of laws and regulations in medical equipments field
    We have well-established system about material purchasing, employee training,store management,after-sales service process.etc


    Our certificates:
    Hospital Device 12.1 Inch Multi-Parameter Patient Monitor

    Latest products from this supplier:

    Hospital Device 12.1 Inch Multi-Parameter Patient Monitor

    Send your message to this supplier

    *From:
    *To:
    avatar Miss Christina Lee
    *Message:

    Enter between 20 to 4,000 characters.

    This is not what you are looking for? Post a Sourcing Request Now