Sichuan, China
Business Type:
Trading Company
Business Range:
Furniture, Health & Medicine, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001, ISO 20000, GMP, ISO 13485
Main Markets:
Europe, Southeast Asia/ Mideast, Africa
OEM/ODM Service
Sample Available

Patient Monitor, Monitor, Touch-Screen Monitor manufacturer / supplier in China, offering ECG NIBP Hospital Medical Equipment 15′′ Multi-Parameter Patient Monitor, Ce Approved Ysd2100-06 Trolley Digital Ultrasound Equipment, Full Digital Laptop Veterinary Ultrasound Scanner CE ISO Approved Ysd3006-Vet and so on.

Gold Member Since 2016
Audited Supplier

ECG NIBP Hospital Medical Equipment 15′′ Multi-Parameter Patient Monitor

Get Latest Price
Purchase Qty. / Reference FOB Price
1-99 Pieces US $750
100+ Pieces US $400
Port: Chengdu, China
Production Capacity: 5000units Per Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram
Medical Devices Reg./Record No.: 141081250003
Medical Device Regulatory Type: Type 2
Classification.: Physiological Functions of Diagnosis and Monitorin
Type.: Patient/Fetal/Maternal Monitor
Monitor: 15 Inch TFT Screen
Battery: Plug-in Rechargeable Battery

You Might Also Like


Basic Info

Model NO.: YSD18D
Warranty: 12 Months
Certificate.: Ce ISO 13485
N.W: 5kg
Origin.: China Chengdu
Export Markets: The Whole World
Color: Black
Trademark: YSD
Transport Package: Carton
Specification: 46*41*32CM
Origin: China Chengdu
HS Code: 9018193010

Product Description

ECG NIBP Hospital Medical Equipment 15'' Multi-Parameter Patient Monitor
Main Feature
15" color Touch-Screen Multi-channel display Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available. Supporting wire or wireless network

ECG NIBP Hospital Medical Equipment 15'' Multi-Parameter Patient Monitor

Lead mode                  5 Leads, I, II, III, AVR, AVL, AVF, V
Gain                        ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,auto
Heart rate                   Measure range:
                             Adult 15 ~ 300 bpm
                             Neonatal/Pediatric 15 ~ 350 bpm
Accuracy                     ±1%
Resolution                    1 bpm
Sensitivity                     > 200 VμP-P
Differential Input Impedance    > 5 M ohm

CMRR                        Monitor Mode >100 dB
                              Surgery Mode >100 dB
                              Diagnostic Mode >90 dB
Electrode offset potential       ±300mV
Leakage Current               < 10 μA
PACE pulse detect             range±2~±700mV
                               width 0.1~2ms
                               rise time 10~100 μs
PACE pulse rejection           range ±2 ~±700mV
                               width 0.1~2ms
                               rise time 10 ~100 μs
Baseline Recovery              < 3 s After defibrillation.
Signal Range                   ±8 mV p-p
Bandwidth           Surgery    1 ~ 20 Hz
                               Monitor 0.5 ~ 40 Hz
                               Diagnostic 0.05 ~ 130 Hz
Calibration Signal               1 mV p-p, 5% accuracy
ST measurement                Range -2.0 ~+2.0 mV
                                ±0.02mV or±10%, which is greater
                                Other range: unspecified
Method                         Impedance between RA-LL
Differential Input Impedance      >2.5 MΩ
Respiration Impedance Range    0.3~3Ω
Base Impedance Range          200Ω~4000Ω
Bandwidth                       0.1 ~ 2.5 Hz
Gain                            ×0.25,×0.500,×1,×2,×4
Respiration Rate                 Measurement Range
                                Adult 0 ~ 120 BrPM
                                 Neonatal / Pediatric 0 ~ 150 BrPM
Resolution                       1 BrPM
Accuracy                         0~6 BrPM: unspecified
                                 7~150 BrPM:±2 BrPM or±2%
                                 use the greater
Inspiriting current                 < 300 A RMS max
Apnea Alarm                     10 ~ 40 s

Method                          Oscillometry
Measure mode                   Manual, Auto, Continual
Measure Interval in AUTO Mode  1,2,3,4,5,10,15,30,60,90,120,180,240,480 min
Measure Period in Continual Mode 5 min
Pulse Rate Range                40 ~ 240 bpm
Measure and Alarm Range      Adult Mode
                                  SYS 40 ~ 270 mmHg
                                  DIA 10 ~ 215 mmHg
                                  MEAN20 ~ 235 mmHg
                                Pediatric Mode
                                   SYS 40 ~ 220 mmHg
                                   DIA 10 ~ 150 mmHg
                                   MEAN20 ~ 165 mmHg
                                Neonatal Mode
                                   SYS 40 ~ 135 mmHg
                                   DIA 10 ~ 100 mmHg
                                   MEAN 20 ~ 110 mmHg
Static pressure accuracy         ±3mmHg
Resolution                       1mmHg
Accuracy                         Maximum Mean error ±5mmHg
                                 Maximum Standard deviation 8mmHg
Overpressure Protection         Adult 297±3 mmHg
                                   Pediatric 240±3 mmHg
                                   Neonatal 147±3 mmHg
Measurement Range                0 ~ 100 %
Resolution                            1 %
Accuracy                           70% ~ 100% ±2 %
                                   0% ~ 39% unspecified
Pulse Rate                         Measure and Alarm Range 20~300bpm
                                   Resolution 1bpm
                                   Accuracy ±3bpm

Measure and Alarm Range0 ~ 50ºC
Accuracy(no sensor)±0.1(25ºC-45ºC),0.2±ºC(other)
Accuracy(include sensor)±0.2ºC(32ºC-42ºC) ±0.3(other) 
ECG NIBP Hospital Medical Equipment 15'' Multi-Parameter Patient Monitor

Other Hot Models:
ECG NIBP Hospital Medical Equipment 15'' Multi-Parameter Patient Monitor

Why choose us:
we got production and business certification from Chengdu food and Drug Administration
we got business license from Chengdu City Administration of industry and commerce
we got products certificate of registration and have checked in the website of CE
we have accepted the onsite check from SFDA every quarter
we finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;
ECG NIBP Hospital Medical Equipment 15'' Multi-Parameter Patient Monitor

Our Certificates:
ECG NIBP Hospital Medical Equipment 15'' Multi-Parameter Patient Monitor

Send your message to this supplier

avatar Miss Christina Lee

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now