Gold Member Since 2016
Audited Supplier
Chengdu Yushengda Technology Co., Ltd.

Patient Monitor, Monitor, Multi-Parameter Patient Monitor manufacturer / supplier in China, offering 12.1 Inch High Qualified Medical Diagnosis Equipment Patient Monitor, Medical Oxygen Concentrator with Low Purity Alarm Pulse Probe Nebulizer, Full Automatic Hospital Product High Qualified Biochemistry Analyzer and so on.

(/ )

Supplier Homepage Product ECG/Patient monitor/Fingertip Pulse Oximeter/Blood Glucose M Monitor 12.1 Inch High Qualified Medical Diagnosis Equipment Patient Monitor

12.1 Inch High Qualified Medical Diagnosis Equipment Patient Monitor

Purchase Qty.:
(Pieces)
1-199 200+
FOB Unit Price: US $750 US $300
Purchase Qty. (Pieces) FOB Unit Price
1-199 US $750
200+ US $300
Get Latest Price
Port: Chengdu, China
Production Capacity: 10000units Per Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YSD16S
  • Type: Patient/Fetal/Maternal Monitor
  • Group: Middle-aged and Old
  • Medical Devices Reg./Record No.: 20142211159
  • Central System : Optional
  • Support Display: 9~13 Waveforms
  • Printer: Built-in High-Speed 50mm Thermal Printer
  • N.W: 3.4kg Excluding Accessories
  • OEM: Support
  • Transport Package: Carton
  • Origin: Chengdu
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, SGS, FDA, EEC, MSDS, ISO13485
  • Medical Device Regulatory Type: Type 2
  • Display: 12.1 Inch High-Brightness TFT LED
  • Resolution: 800*600 Pixels
  • Export Markets: The Whole World
  • Touch Screen: Support
  • USB Port: 1
  • Trademark: YSD
  • Specification: 310MM*290MM*150MM
  • HS Code: 90181930
Product Description
YSD16S Multi-parameter Patient Monitor (12.1 inches)
Technical Data Sheet - Release
The YUSHENGDA YSD16S patient monitor is designed to match the pace and unique needs of adult, pediatric, and neonatal intensive care; anesthesia and peri-operative care; OR and cardiac care environments.
An optional USB Mouse/Keyboard control eases navigation and data entry.
An optional HDMI output eases observation from a long distance

Features:
Core 
Newly advanced A8 main board with Linux OS, calculating speed is 4 times faster than traditional products 
Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review
 
Body
12.1 inch high-brightness TFT LED
Support display 9~13 waveforms
Support 7 channel ECG waveform display simultaneously 
Optional touch screen
Optional HDMI output
 
Printer 
Built-in high-speed 50mm thermal printer (Brand: SEIKO, Japan)
Central System 
Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
Optional Support HL7 (Health Level Seven) 
Three-level acousto-optic alarm
Sensor-off alarm
Paper out alarm
Support alarm review
Support alarm pause
 
Service Features:

The Support Tool helps technical personnel to back up the monitor settings.
 
The Service Mode is password-protected and ensures that only trained staff can access service tests and tasks. It includes Skin Type, Brightness
NIBP Review 
Setting, Clear Data, NIBP Calibration and Touch Screen Calibration.
The Support Tool uses the USB interface of the monitor for software upgrading.
Performance Specifications
 
Dimension and Weight 
Dimension: 310mm*290mm*150mm
Weight: 3.4kg(excluding accessories)
Power Supply: Voltage: AC100~240V, 50/60HZ, Power≤60W
Display: 12.1" color TFT LED 
Resolution: 800*600 pixels
Battery (Pluggable) 
Type: Rechargeable lithium battery 14.8V/2200mAh
Charge Cycle: ≥500 times
Working time: 2 hours (optional larger battery for 4-5 hours)
Recorder (Option) 
Method: Thermal printer
Paper width: 50 mm (1.97 in)
Printing speed: 12.5/ 25/ 50 mm/s
Trace: Max. 3 tracks
Recording way: Real-time Recording, Review Printing, 
Periodic Recording, Alarm Recording
 
Alarm 
Level: Low, medium and high
Indication: Auditory and visual
Alarm volume adjustable
Alarm pause time: 1min, 2min
Parameter alarm type: Latch/ Unlatch
 
Input Device 
Touch screen (option)
Knob (Standard)
Keypad input (Standard)
Mouse/ Keyboard input (option)
 
System Output & Extensible Interface 
Ethernet Network: 1 standard RJ45 socket
USB Port: 1
Video Output: 1 HDMI port (option)
 
Operating Environment 
Temperature:  5 ~ 40 ºC
Humidity:  15% ~ 80% (non-condensing)
Atmosphere pressure:  86 KPa ~ 110 KPa
Transportation and Storage Environment
 
Temperature:  -20~50 ºC
Humidity:  10%~90%  (non-condensing)
Atmosphere pressure:  86 KPa ~ 110 KPa
 

Performance Specifications:
 
SpO2 (Digital Technic)
Measurement Range: 0 ~ 100 %
Resolution: 1 %
Accuracy:  ±2% (70% ~ 100%)
            ±3 % (35% ~ 69%)
Unspecified (0 ~ 34%)
Support Pitch tone and multi-level volume  
 
Pulse Rate
Measuring and Alarm Range: 25~250bpm
Accuracy: ±1% or ±1 bpm, whichever is greater
Resolution: 1bpm
 
Nellcor-SpO2 (Option)
Measurement Range: 0 ~ 100 %
Resolution:    1 %
Accuracy:     70% ~ 100%, ±2 % (adult)
              70% ~ 100%, ±3 % (Neonate)
              70% ~ 100%, ±2 % (Low Perfusion)
              0% ~ 69%, unspecified
 
Pulse Rate
Measurement range: 20 ~ 300 bpm
Resolution: 1bpm
Accuracy:
±3 bpm (20 ~ 250 bpm)
unspecified (251~300 bpm)
 
Masimo SpO2 (Option)
- Measurement Range: 0 ~ 100 %
- Resolution: 1 %
Accuracy: 
70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
70% ~ 100%, ±3 % (neonate, non-motion conditions)
70% ~ 100%, ±3 % (motion conditions)
0% ~ 69% unspecified
Pulse Rate
Measurement range: 25 ~ 240 bpm
Resolution: 1bpm
Accuracy: ±3 bpm (non-motion condition)
 EtCO2 (Mainstream/ Sidestream) (Option)
Measure method:  Non-dispersive infrared (NDIR)
Measure Range:  0 ~19.7% (0 ~ 150 mmHg)
                 0 ~ 20 kPa
Resolution: 0.1 mmHg
CO2 Accuracy: 
0 ~ 40 mmHg, ±2 mmHg
41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading
101~ 150 mmHg, ±10% of reading
at 760 mmHg, ambient temperature of 25ºC)
Respiratory Rate:  Range: 3 ~150 BrPM
                  Accuracy: ±1 bpm
 
EtCO2 (Micro-stream) (Option)
Measure method:  Non-dispersive infrared (NDIR)
Measure Range:  0 ~19.7% (0 ~150 mmHg)
                 0 ~ 20 kPa
Sample Rate: 50 mL/min ±10mL/min
Resolution:  0.1 mmHg (0 ~ 50 mmHg)
           0.25 mmHg (50 ~ 114 mmHg)
CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg
                41 ~ 70 mmHg, ±5% of reading
                71 ~ 100 mmHg, ±8% of reading
               101~ 150 mmHg, ±10% of reading
        at 760 mmHg, ambient temperature of 35ºC)
Respiratory Rate: Range: 3 ~120 BrPM
                 Accuracy: ±1 bpm
 
Depth of Anesthesia (CSI) (Option)
EEG sensitivity:  ± 400μV
Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz
CMRR: > 140 dB
Input impedance: > 50 Mohm
Sample rate: 2000 samples/sec, (14 bits equivalent)
BS%: 0-100, filter 1-42 Hz, 1 sec. display update
EMG: 0-100 Logarithmic. Filter 75-85 Hz, 1 sec. update
Alarms: High / Low with user selectable limit
Artifact rejection: Automatic
Sensor impedance range: 0 - 10 kOhm / measurement current 0.01 μA
Multi-gas/O2 (Anesthetic Gas) (Option)
Method: Infrared absorption
Gas sorts: CO2, N2O, Des, Iso, Enf, Sevo, Hal,
   O2 (Optional paramagnetic sensor)
Calibration: Room air calibration performed automatically when changing airway
Airway adapt (< 5 sec)
Measurement range:
CO2: 0~25%,  N2O : 0~100%                   
O2: 0~100%,  Enf, Iso, Hal: 0~25%,
Sevo, Des: 0~25%
Data output: Fi and ET values
Respiration rate: 0~ 150 BrPM
Other: Up to 5 waveforms displayed
      Agent mixture detection
  MAC value displayed
 
IBP (Option)
Max Channel: 2
Measurement way: Thermal resistance way
Press Sensor:  Sensitivity   5 uV/V/mmHg, ±2%
              Impedance   300 to 3000Ω
Resolution: 1 mmHg
Unit: mmKg, kPa, cmH2O
Transducer sites: 
Arterial Pressure (ART)
Pulmonary Arterial (PA)
Left Arterial (LAP)
Right Arterial (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/ P2
Measuring and alarm range:
ART                               0 ~ +350mmHg
PA                                 -10 ~ +120 mmHg
CVP/ RAP/ LAP/ ICP -10 ~ +40 mmHg
P1/ P2                                           -50 ~ +350mmHg
Accuracy: 
Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer)
      ±4mmHg or ±4%, whichever is greater (inclusive of transducer)
Dynamic:  ±4mmHg or ±4%, whichever is greater
  



 
Send your message to this supplier
Avatar
Mr. Justin
*From:
To: Mr. Justin
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now