Gold Member Since 2016
Audited Supplier
Chengdu Yushengda Technology Co., Ltd.

Patient Monitor, Moniotr, Multi-Parameter Patient Monitor manufacturer / supplier in China, offering 12 Inch Digital Multi-Parameter Patient Monitor, Digital Touch-Screen iPad Model Plamtop Ultrasound Ysd3200 CE Approved, Ysd4000b Ce ISO SGS Approved Veterinary Laptop Digital Ultrasound and so on.

(/ )

12 Inch Digital Multi-Parameter Patient Monitor

Purchase Qty.:
(Pieces)
1-99 100+
FOB Unit Price: US $460 US $300
Purchase Qty. (Pieces) FOB Unit Price
1-99 US $460
100+ US $300
Get Latest Price
Port: Chengdu, China
Production Capacity: 5000
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YSD16L
  • Type: Patient/Fetal/Maternal Monitor
  • Group: Middle-aged and Old
  • Medical Devices Reg./Record No.: 20142540865
  • Option: IBP, Etco2 and 2-IBP
  • Display: 12.1" Color TFT Display
  • Warranty: 12 Months
  • OEM: Acceptable
  • N.W: 1.5kg
  • Transport Package: in Carton Packing
  • Origin: China Chengdu
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, SGS, FDA, ISO13485
  • Medical Device Regulatory Type: Type 2
  • 6 Standard Parameters: ECG, Resp, NIBP, SpO2, 2-Temp, Pr/Hr
  • Certification.: Ce, ISO13485
  • Color: White
  • Export Markets: The Whole World
  • Etco2: Optional
  • Trademark: YSD
  • Specification: 210mm*185mm*100mm
  • HS Code: 90181930
Product Description
YSD16L is a robust patient monitor, small enough to move around, yet flexible enough to adapt to your particular needs. With a variety of optional extras, including arrhythmia and ST analysis, EtCO2 measurement and double IBP.
YSD16L is configurable to suit your requirements. Purchase only the advanced features that you need and nothing more. With NIBP recall and extensive data storage capability .
YSD16L is particularly well-suited for use in peri-anesthesia and critical care environments. Rich in functions, conveniently adaptable and pleasingly affordable.

Main Features 

a). 6 Standard parameters: ECG, RESP, NIBP, SPO2, 2-TEMP, PR/HR.
b). 12.1"high resolution color TFT LCD display.
c). Real time S-T segment analysis, pace-maker detection.
d). Indication of Incorrect manipulation and malfunction analysis.
e). Multichannel display 
f). Big font interface
g). ST and arrhythmia analysis
h). Drug dose calculation and titration table
i). OxyCRG dynamic view display
j). Respiration monitoring with apnea alarms
k). Alarm review, arrhythmia review 
l). Patient info. Input 
m). Antidefibrillation design
n). NIBP over pressure protection
o). Plugin rechargeable battery, AC/DC available. 
p). Supporting wire or wireless network.
q). Patient info input management function
r). Multi-lead ECG waveforms display in phase.
s). Large volume of tabular and graphic trends information storage and easy to recall.
t). Capture dynamic waveforms.
u). Efficient resistance to interference of defibrillator and HF knife.
v). UP to 2 hours working capacity of built-in rechargeable battery.
w). Unique accessory management cabinet.
x). Option: IBP, ETCO2 and 2-IBP.
 
Standard configuration:

SPO2,PR,NIBP,ECG,RESP,TEMP

Optional configuration:
ETCO2

Technical Specifications:
 
ECG
Lead Mode              5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection           I, II, III, avR, avL, avF, V
Wavef orm              2 ch
Lead mode              3 Leads ( R, L, F or RA, LA, LL) 
Lead selection           I, II, III,
Wave form              1 ch
Gain                    2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
 
HR and Alarm Range        Adult    15 ~ 300 bpm
                            Neo/Ped    15 ~ 350 bpm
Accuracy                    ±1% or±1bpm, which is greater
Resolution                  1 bpm 
Sensitivity                   > 200 (uVp-p) 
Differential Input Impedance  > 5 MΩ
 
CMRR                      Monitor > 105 dB 
                            Operation > 105 dB 
                            Diagnosis > 85 dB
Electrode offset potential     ±300mV 
Leakage Current            < 10 uA
Baseline Recovery           < 3 S After Defi. 
ECG Signal Range          ±8 m V ( Vp-p ) 
 
Bandwidth                   Surgery    1 ~ 20 Hz
                            Monitor     0.5 ~ 40 Hz
                            Diagnostic  0.05 ~ 130 Hz
Calibration Signal            1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range   Measure and Alarm -2.0 ~ +2.0 mV
 
ARR Detecting               Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY,
                             TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS,
                             PNP, PNC,Alarm Available,Review Available
 
Respiration
 
Method                      Impedance between R-F(RA-LL)
Differential Input Impedance         > 2.5 MΩ
Measuring Impedance Range        0.3~3 Ω
Base line Impedance Range        200~4 KΩ
Bandwidth                         0.1~2.5Hz
Resp. Rate                  Measuring and Alarm Range
                            Adult 0 ~ 120 Brpm 
                            Neo/Ped 0 ~ 150 Brpm 
                            Resolution 1 Brpm 
                            Accuracy ±2 Brpm
 
Apnea Alarm                10 ~ 40 S
 
NIBP 
 
Method                     Oscillometric
Mode                       Manual, Auto, STAT                        
Measuring Interval in AUTO Mode       1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode        5 Min
Pulse Rate Range                     40 ~ 240 bpm
Alarm Type                            SYS, DIA, MEAN
 
Measuring and alarm range          
 Adult Mode
                            SYS 40 ~ 270 mmHg 
                            DIA 10 ~ 215 mmHg 
                            MEAN 20 ~ 235 mmHg
Pediatric Mode
                            SYS 40 ~ 200 mmHg 
                            DIA 10 ~ 150 mmHg 
                            MEAN 20 ~ 165 mmHg
Neonatal Mode
                            SYS 40 ~ 135 mmHg 
                            DIA 10 ~ 100 mmHg 
                            MEAN 20 ~ 110 mmHg
Resolution                  1mmHg
 
Accuracy                   Maximum Mean error ±5mmHg
                           Maximum Standard deviation ±8mmHg
Overpressure Protection    Adult Mode 297±3 mmHg 
                           Pediatric Mode 240±3 mmHg 
                           Neonatal Mode 147±3 mmHg
 
SpO2
Measuring Range          0 ~ 100 % 
Alarm Range              0 ~ 100 % 
Resolution                 1 %
Accuracy                  70% ~ 100%  2 %
                          0%  ~  69% unspecified
Actualization intervalabout  1 Sec. 
Alarm Delay               10 Sec.
Pulse Rate                Measuring and Alarm Range 20~300 bpm
                          Resolution       1bpm
                          Accuracy         ±3bpm
                                   
TEMP
 
Channel                        2
Measuring and Alarm Range    0 ~ 50 ºC
Resolution                     0.1 ºC
Accuracy                      ±0.2 ºC
Actualization intervalabout       1 Sec.
Average Time Constant         < 10 Sec.
 
 
IBP
 
Label                              ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range         ART 0 ~ 300 mmHg 
                                   PA -6 ~ 120 mmHg
                                   CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                                   P1 / P2-10 ~ 300 mmHg 
 
 
Press Sensor                      Sensitivity 5  uV/V/mmHg
                                   Impedance 300-3000Ω
 
Resolution                         1 mmHg
Accuracy                          ±2% or 1mmHg which is greater
Actualization interval               about 1 secretary
 
Standard:
ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature

Optional:  
Nellcor SpO2, EtCO 2, IBP, Thermal Recorder

Parameters Sheet:
NIBPMethod:Oscillometry
Modes:Manual/Auto/Comtinuous  
Auto measure time:Adjustable
Measurement range:10-300mmHg
 
ECG  
 
 
 
 
Lead mode: 3-lead or 5-lead
Lead selection: I;II;III,avR;avF;V  
Heart rate range: Adult:15-300bpm;
Pediatric/Neonatal:15-300bpm  
ECG waveform: 2 channals  
Accuracy: ±1 bpm or ±1%,which is greater  
S-T segment detection;measurement range: -2.0mv~+2.0mv  
Alarm:Yes,audible and  visual alarm,alarm events review
 SPO2Measurement range:0-100%  
Accuracy:70-100%,±2%,0-69%,upspecified  
Auto measure time:Adjustable
 
Pulse Rate
Range:20-254bpm  
Accuracy: ±3bpm
 
Respiration
Method:RA-LL impedance  
Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm  
 Apnca alarm:Yes
TemperatureRange:0-500
Accuracy: ± 0.10  
Channal:Dual-channel
 Main unitECG cable
Spo2 probe
TEM Probe
NIBP Tube
Adult cuff
Power cable
Battery
User manual

Why Choose us
* Professional manufacture for 7 years
* Various medical equipment for your selection
* Good after-sales services agreement
* Favourable and Competitive price
* Stable quality

Why choose us:
we got production and business certification from Chengdu food and Drug Administration
we got business license from Chengdu City Administration of industry and commerce
we got products certificate of registration and have checked in the website of SFDA
we have accepted the onsite check from SFDA every quarter
we finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;

 
Send your message to this supplier
Avatar
Mr. Wizard
*From:
To: Mr. Wizard
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now