Gold Member Since 2016
Audited Supplier
Chengdu Yushengda Technology Co., Ltd.

Patient Monitor, Monitor, Multi-Parameter Patient Monitor manufacturer / supplier in China, offering Ce Multi-Channel Medical Equipment 15′′ Touch Screen Patient Monitor, Portable Medical Machine Veterinary Ultrsound Scanner, Ce Approved Diagnostic System 3D/4D Color Doppler Ultrasound and so on.

(/ )

Supplier Homepage Product ECG/Patient monitor/Fingertip Pulse Oximeter/Blood Glucose M Monitor Ce Multi-Channel Medical Equipment 15′′ Touch Screen Patient Monitor

Ce Multi-Channel Medical Equipment 15′′ Touch Screen Patient Monitor

Purchase Qty.:
(Pieces)
1-999 1,000+
FOB Unit Price: US $700 US $1
Purchase Qty. (Pieces) FOB Unit Price
1-999 US $700
1,000+ US $1
Get Latest Price
Port: Chengdu, China
Production Capacity: 10000units Per Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YSD18D
  • Type: Patient/Fetal/Maternal Monitor
  • Group: Middle-aged and Old
  • Medical Devices Reg./Record No.: 20142230425
  • Type.: Patient/Fetal/Maternal Monitor
  • Battery: Plug-in Rechargeable Battery
  • OEM: Acceptable
  • Manufacture: Yes
  • Color: Black
  • Transport Package: Carton
  • Origin: China Chengdu
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, FDA, MSDS, ISO13485
  • Medical Device Regulatory Type: Type 2
  • Standard Parameters: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temp
  • Monitor: 15 Inch TFT Screen
  • Warranty: 12 Months
  • G.W: 3.5kg
  • Export Markets: The Whole World
  • Trademark: YSD
  • Specification: 460*410*320mm
  • HS Code: 90181210
Product Description

Ce Multi-Channel Medical Equipment 15'' Touch Screen Patient Monitor
Main Feature:

Δ. 15" color TFT screen Multi-channel display Big font interface
Δ. ST and arrhythmia analysis
Δ. Drug dose calculation and titration table
Δ. OxyCRG dynamic view display
Δ. Respiration monitoring with apnea alarms
Δ. Alarm review, arrhythmia review
Δ. Patient info. Input
Δ. Anti-defibrillation design
Δ. NIBP over pressure protection
Δ. Plug-in rechargeable battery, AC/DC available. Supporting wire or wireless network
Ce Multi-Channel Medical Equipment 15'' Touch Screen Patient Monitor

Specifications

ECG
Lead mode               5 Leads, I, II, III, AVR, AVL, AVF, V
Gain                        ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV,auto
Heart rate                 Measure range:
                               Adult 15 ~ 300 bpm
                               Neonatal/Pediatric 15 ~ 350 bpm
Accuracy                      ±1%
Resolution                    1 bpm
Sensitivity                     > 200 VμP-P
Differential Input Impedance    > 5 M ohm

CMRR                    Monitor Mode >100 dB
                              Surgery Mode >100 dB
                              Diagnostic Mode >90 dB
Electrode offset potential       ±300mV
Leakage Current                   < 10 μA
PACE pulse detect                range±2~±700mV
                                           width 0.1~2ms
                                           rise time 10~100 μs
PACE pulse rejection            range ±2 ~±700mV
                               width 0.1~2ms
                               rise time 10 ~100 μs
Baseline Recovery    < 3 s After defibrillation.
Signal Range             ±8 mV p-p
Bandwidth        Surgery    1 ~ 20 Hz
                           
                       Monitor 0.5 ~ 40 Hz
                       Diagnostic 0.05 ~ 130 Hz
Calibration Signal       1 mV p-p, 5% accuracy
ST measurement        Range -2.0 ~+2.0 mV
                                Accuracy-0.8mV~+0.8mV
                                ±0.02mV or±10%, which is greater
                                Other range: unspecified
Respiration
Method                     Impedance between RA-LL
Differential Input Impedance      >2.5 MΩ
Respiration Impedance Range     0.3~3Ω
Base Impedance Range              200Ω~4000Ω
Bandwidth                          0.1 ~ 2.5 Hz
Gain                                  ×0.25,×0.500,×1,×2,×4
Respiration Rate                 Measurement Range
                                        Adult 0 ~ 120 BrPM
                                        Neonatal / Pediatric 0 ~ 150 BrPM
Resolution                        1 BrPM
Accuracy                          0~6 BrPM: unspecified
                                       7~150 BrPM:±2 BrPM or±2%
                                       use the greater
Inspiriting current               < 300 A RMS max
Apnea Alarm                     10 ~ 40 s

NIBP
Method                             Oscillometry
Measure mode                   Manual, Auto, Continual
Measure Interval in AUTO Mode  1,2,3,4,5,10,15,30,60,90,120,180,240,480 min
Measure Period in Continual Mode 5 min
Pulse Rate Range                   40 ~ 240 bpm
Measure and Alarm Range      Adult Mode
                                  SYS 40 ~ 270 mmHg
                                  DIA 10 ~ 215 mmHg
                                  MEAN20 ~ 235 mmHg
                              Pediatric Mode
                                   SYS 40 ~ 220 mmHg
                                   DIA 10 ~ 150 mmHg
                                   MEAN20 ~ 165 mmHg
                              Neonatal Mode
                                   SYS 40 ~ 135 mmHg
                                   DIA 10 ~ 100 mmHg
                                   MEAN 20 ~ 110 mmHg
Static pressure accuracy   ±3mmHg
Resolution                       1mmHg
Accuracy                    Maximum Mean error ±5mmHg
                                 Maximum Standard deviation 8mmHg
Overpressure Protection         Adult 297±3 mmHg
                                   Pediatric 240±3 mmHg
                                   Neonatal 147±3 mmHg
SpO2
Measurement Range             0 ~ 100 %
Resolution                           1 %
Accuracy                            70% ~ 100% ±2 %
                                          69%
                                          0% ~ 39% unspecified
Pulse Rate                   Measure and Alarm Range 20~300bpm
                                   Resolution 1bpm
                                   Accuracy ±3bpm
Temperature
Channel2
Measure and Alarm Range0 ~ 50ºC
Resolution0.1ºC
Accuracy(no sensor)±0.1(25ºC-45ºC),0.2±ºC(other)
Accuracy(include sensor)±0.2ºC(32ºC-42ºC) ±0.3(other)
Ce Multi-Channel Medical Equipment 15'' Touch Screen Patient Monitor

Why choose us:
we got production and business certification from Chengdu food and Drug Administration
we got business license from Chengdu City Administration of industry and commerce
we got products certificate of registration and have checked in the website of SFDA
we have accepted the onsite check from SFDA every quarter
we finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;

our certificates:
Ce Multi-Channel Medical Equipment 15'' Touch Screen Patient Monitor


Similar Model:
Ce Multi-Channel Medical Equipment 15'' Touch Screen Patient Monitor
Ce Multi-Channel Medical Equipment 15'' Touch Screen Patient Monitor


 
Send your message to this supplier
Avatar
Miss Christina Lee
Export Director
*From:
To: Miss Christina Lee
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now