Gold Member Since 2016
Audited Supplier
Chengdu Yushengda Technology Co., Ltd.

Patient Monitor, Portable Patient Monitor, Multi-Parameter Patient Monitor manufacturer / supplier in China, offering 15 Inch High Qualified Portable Patient Monitor Hopital Equipment, Ysd Modern Design Veterinay Medical Instrument Portable Palm Ultrasound Scanner, Cheapest Scanner Medical Equipment Wirelessusg Linear Convex Probe Ultrasound and so on.

(/ )

Supplier Homepage Product ECG/Patient monitor/Fingertip Pulse Oximeter/Blood Glucose M Monitor 15 Inch High Qualified Portable Patient Monitor Hopital Equipment

15 Inch High Qualified Portable Patient Monitor Hopital Equipment

Purchase Qty.:
(Pieces)
1-99 100+
FOB Unit Price: US $900 US $650
Purchase Qty. (Pieces) FOB Unit Price
1-99 US $900
100+ US $650
Get Latest Price
Port: Chengdu, China
Production Capacity: 10000units Per Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YSD18L
  • Type: Patient/Fetal/Maternal Monitor
  • Group: Middle-aged and Old
  • Medical Devices Reg./Record No.: 20142211159
  • Print-Speed Selectable: 1cm/Mincm/Mincm/Minmm/Sec
  • Measurement Range: 30~240bpm
  • N.W: 3.5kg
  • Payment: T/T , Western Union
  • Optional: Etco2
  • Transport Package: Carton
  • Origin: Chengdu
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, FDA, EEC, MSDS, ISO13485
  • Medical Device Regulatory Type: Type 2
  • Display: 15" LED
  • Warranty: 12 Months
  • Color: White
  • Delivery Time: 5~7 Working Days After Receiving Full Payment
  • Paper Width: 50 mm (1.97 in)
  • Trademark: YSD
  • Specification: 400mm*300mm*280mm
  • HS Code: 90181930
Product Description
YSD18L 15" Multi-parameter Patient Monitor

Product Description:

Newly advanced YSD18L main board with Linux OS, calculating speed is 4 times faster than traditional products.
Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review


Performance Specifications

1. Dimension: 393mm*382mm*173mm

2. Weight: 4.5kg(excluding accessories)

3. Voltage: AC100~240V, 50/60HZ, Power≤60W

4. Display: 15" color TFT LED 

5. Resolution: 1024*768 pixels

6. Battery: Rechargeable lithium battery 14.8V/2200mAh (Pluggable)
           Charge Cycle: ≥500 times
           Working time: 2 hours (optional larger battery for 4-5 hours)

7. Recorder(Optional):
   Method: Thermal printer
   Paper width: 50 mm (1.97 in)
   Printing speed: 12.5/ 25/ 50 mm/s
   Trace: Max. 3 tracks
   Recording way: Real-time Recording, Review Printing, 
   Periodic Recording, Alarm Recording

8. Alarm:
   Level: Low, medium and high
   Indication: Auditory and visual
   Alarm volume adjustable
   Alarm pause time: 1min, 2min
   Parameter alarm type: Latch/ Unlatch

9. Input Device:
  Touch screen (option)
  Knob (Standard)
  Keypad input (Standard)
  Mouse/ Keyboard input (option)

10 System Output & Extensible Interface
    Ethernet Network: 1 standard RJ45 socket
    USB Port: 1
    Video Output:  1 HDMI port (option)

11. Operating Environment
    Temperature:  5 ~ 40 ºC
    Humidity:  15% ~ 80% (non-condensing)
    Atmosphere pressure:  86 KPa ~ 110 KPa

12. Transportation and Storage Environment
    Temperature:  -20~50 ºC
    Humidity:  10%~90%  (non-condensing)
    Atmosphere pressure:  86 KPa ~ 110 KPa

13. Safety
    IEC60601-1 Approved, CE marking according to MDD93/42/EEC
    With reference to RoHS Directive 2011/65/EU recasting

14. Trend & Reviewing
    Trend: 2160 hours
    ARR events: 128 groups of ARR events and associated waveform
    NIBP measurement reviewing: 2000 groups
    Waveform review: 2 hours
    Alarm event: 2000 groups of parameter alarms events and associated parameter

15. Body
    15 inch high-brightness TFT LED
    Support display 9~13 waveforms
    Support 7 channel ECG waveform display simultaneously 
    Optional HDMI output

16. Printer
    Built-in high-speed 50mm thermal printer (Brand: SEIKO, Japan)  

17. Central System
    Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
    Optional Support HL7 (Health Level Seven)

18. Alarm Timing
    Double high light alarm light bar.
    Three-level acousto-optic alarm
    Sensor-off alarm
    Paper out alarm
    Support alarm review
    Support alarm pause 

19. Linux OS
    Support operation with mouse and computer keyboard (option)
    Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph,
    NIBP review and full leads ECG interface.
    NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
    Generate ID automatically when register a new patient
    Support medical history search by patient ID, name and mobile number
    18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
    Drug calculation and titration table
    Support multi-language display
    Support online software upgrading by net/USB


20. LAN / Central monitor system interface
    The LAN port is for connecting the monitor to a central monitor system network.  

21. Input device interface
    This optional interface provides an USB ports to enable the monitor to be connected to off-the-shelf input devices:
    Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
    Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
    [Remark: user has to restart the machine after plug and unplug the mouse / computer keyboard.]



Technical Parameters:

1. ECG

   Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
   Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
   Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
   Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
   ECG signal range:  ±12 mV (Gain × 0.25)
   Accuracy: ±1bpm/ ±1%, whichever is greater
   Resolution: 1 bpm
   Leakage Current < 10 μA
   Baseline Recovery: ≤ 3s after defibrillation (Monitor mode)≤ 1s after defibrillation (Surgery mode)
   Bandwidth: Surgery 1 ~ 25 Hz
   Monitor 0.5 ~ 40 Hz
   Diagnostic 0.05 ~ 120 Hz
   Indication of Electrode Separation: Every electrode (exclusive of RL)

2. Heart Rate

   Measure range: Adult: 0bpm; 10 ~ 300 bpmNeo/Ped: 0bpm; 10 ~ 350 bpm
   Resolution: 1 bpm
   Accuracy: ± 1% or ± 1bpm, whichever is greater

3. ST Measurement

   Range: -2.0 ~ +2.0 mV
   Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
   Other range: unspecified
   Resolution: 0.01mV

4. Respiration

   Method: Impedance between RA-LL, RA-LA
   Gain: ×0.25, ×0.50, ×1, ×2, ×4
   Respiration Rate: 0bpm, 6 ~ 150 BrPM
   Sweep speed:  6.25 mm/s, 12.5 mm/s, 25mm/s
   Resolution: 1 BrPM
   Accuracy: ±2 bpm or ±2%, whichever is greater
   Apnea Alarm: 10 ~ 60 s

5. NIBP

   Method: Oscillometric
   Measure mode: Manual, Auto, STAT
   Measure Interval in AUTO Mode 1~480 min
   STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
   Measure and Alarm Range:
   Adult:   SYS:  30 ~ 270 mmHg    Pediatric:   SYS:  40 ~ 235 mmHg DIA: 10 ~ 220 mmHg   MEAN:  20 ~ 225 mmHg
   Neonate:  SYS:  30 ~ 135 mmHg DIA: 10 ~ 110 mmHg   MEAN:  20 ~ 125 mmHg Static pressure accuracy: ±3mmHg
   Resolution: 1mmHg
   Accuracy: Maximum Mean error ±5mmHg  Maximum Standard deviation ≤8mmHg
   Over pressure Protection: Dual protection via software & hardware

6. Temperature

   Technique: Thermistor probe (2.25K)
   Channel:  Dual-channel, provide T1; T2; ΔT
   Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
   Unit: Celsius (ºC), Fahrenheit ( ºF)
   Resolution: 0.1ºCor 1ºF
   Accuracy: ±0.1ºC(exclusive probe)



Performance Specifications

1. SpO2 (Digital Technic)

   Measurement Range: 0 ~ 100 %
   Resolution: 1 %
   Accuracy:  ±2% (70% ~ 100%)  ±3 % (35% ~ 69%)  Unspecified (0 ~ 34%)
   Support Pitch tone and multi-level volume  

2. Pulse Rate

   Measuring and Alarm Range: 25~250bpm
   Accuracy: ±1% or ±1 bpm, whichever is greater
   Resolution: 1bpm

3. Nellcor-SpO2 (Option)

   Measurement Range: 0 ~ 100 %
   Resolution: 1 %
   Accuracy:   70% ~ 100%, ±2 % (adult)          70% ~ 100%, ±3 % (Neonate)
               70% ~ 100%, ±2 % (Low Perfusion)  0% ~ 69%, unspecified

4. Pulse Rate

   Measurement range: 20 ~ 300 bpm
   Resolution: 1bpm
   Accuracy: ±3 bpm (20 ~ 250 bpm)  unspecified (251~300 bpm)

5. Masimo SpO2 (Option)-

   Measurement Range: 0 ~ 100 %-
   Resolution: 1 %
   Accuracy:  70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
              70% ~ 100%, ±3 % (neonate, non-motion conditions)
              70% ~ 100%, ±3 % (motion conditions)
              0% ~ 69% unspecified

6. Pulse Rate

   Measurement range: 25 ~ 240 bpm
   Resolution: 1bpm
   Accuracy: ±3 bpm (non-motion condition)

7. EtCO2 (Mainstream/ Sidestream) (Option)

   Measure method:  Non-dispersive infrared (NDIR)
   Measure Range:  0 ~19.7% (0 ~ 150 mmHg)  0 ~ 20 kPa
   Resolution: 0.1 mmHg
   CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg41 ~ 70 mmHg, ±5% of reading71 ~ 100 mmHg, ±8% of reading101~ 150 mmHg,
   ±10% of reading at 760 mmHg, ambient temperature of 25ºC)
   Respiratory Rate:  Range: 3 ~150 BrPM      Accuracy: ±1 bpm


8. EtCO2 (Micro-stream) (Option)

   Measure method:  Non-dispersive infrared (NDIR)
   Measure Range:  0 ~19.7% (0 ~150 mmHg) 0 ~ 20 kPa
   Sample Rate: 50 mL/min ±10mL/min
   Resolution:  0.1 mmHg (0 ~ 50 mmHg  )0.25 mmHg (50 ~ 114 mmHg)
   CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading
   71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of readingat 760 mmHg, ambient temperature of 35ºC)
   Respiratory Rate: Range: 3 ~120 BrPM
   Accuracy: ±1 bpm

9. Depth of Anesthesia (CSI) (Option)

   EEG sensitivity:  ± 400μV
   Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz
   CMRR: > 140 dB
   Input impedance: > 50 Mohm
   Sample rate: 2000 samples/sec, (14 bits equivalent)
   BS%: 0-100, filter 1-42 Hz, 1 sec. display update
   EMG: 0-100 Logarithmic. Filter 75-85 Hz, 1 sec. update
   Alarms: High / Low with user selectable limit
   Artifact rejection: Automatic
   Sensor impedance range: 0-10 kOhm / measurement current 0.01 μA

10. Multi-gas/O2 (Anesthetic Gas) (Option)

   Method: Infrared absorption
   Gas sorts: CO2, N2O, Des, Iso, Enf, Sevo, Hal, O2 (Optional paramagnetic sensor)
   Calibration: Room air calibration performed automatically when changing airway
   Airway adapt (< 5 sec)
   Measurement range: CO2: 0~25%,  N2O : 0~100%   O2: 0~100%,  Enf, Iso, Hal: 0~25%, Sevo, Des: 0~25%
   Data output: Fi and ET values
   Respiration rate: 0~ 150 BrPM
   Other: Up to 5 waveforms displayed 
   Agent mixture detection 
   MAC value displayed

11. IBP (Option)

   Max Channel: 2
   Measurement way: Thermal resistance way
   Press Sensor: Sensitivity   5 uV/V/mmHg, ±2%-
   Impedance   300 to 3000Ω
   Resolution: 1 mmHg
   Unit: mmKg, kPa, cmH2O
   Transducer sites: 
   Arterial Pressure (ART)
   Pulmonary Arterial (PA)
   Left Arterial (LAP)
   Right Arterial (RAP)
   Central Venous Pressure (CVP)
   Intracranial Pressure (ICP)
   P1/ P2
   Measuring and alarm range:
   ART        0 ~ +350mmHgPA   -10 ~ +120 mmHgCVP/ RAP/ LAP/ ICP    -10 ~ +40 mmHg P1/ P2    -50 ~ +350mmHg
   Accuracy:  Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer)±4mmHg or ±4%,
   whichever is greater (inclusive of transducer)
   Dynamic:  ±4mmHg or ±4%, whichever is greater



Model Configuration
 
Standard15 inch LED,
3/5 Lead ECG,
NIBP,
SpO2,
Pulse Rate,
Temperature,
Respiration
Optional1/2 IBP,
2-Temperature,
Nellcor SpO2,
Masimo SpO2, 
EtCO2 (Mainstream/Sidestream/Microstream), 
Anesthesia Depth Monitoring (CSM module), 
Multi-gas (AG) Monitoring.
Optional AccessoriesTouch Screen,
Printer,
USB Mouse/Computer Keyboard Input Function, 
Central Monitoring Station, N
eo/Ped Accessories, HDMI Output, Wall-mounting, Trolley,



Why choose us:
We got production and business certification from Chengdu food and Drug Administration
We got business license from Chengdu City Administration of industry and commerce
We got products certificate of registration and have checked in the website of SFDA
We have accepted the onsite check from SFDA every quarter
we finished the training of laws and regulations in medical equipments field
We have well-established system about material purchasing, employee training,store management,after-sales service process.etc
We adheres the beliefs of "Support Healthy Life", and our company spirits are quality, service,trust,thanksgiving;
 
Send your message to this supplier
Avatar
Miss Doris
Regional Manager
*From:
To: Miss Doris
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now