Gold Member Since 2016
Audited Supplier
Chengdu Yushengda Technology Co., Ltd.

Patient Monitor, Portable Patient Monitor, Multi-Parameter Patient Monitor manufacturer / supplier in China, offering Ysd18L Hot Sale Multi-Parameter Medical Equipment Patient Monitor, Medical Oxygen Concentrator with Low Purity Alarm Pulse Probe Nebulizer, Full Automatic Hospital Product High Qualified Biochemistry Analyzer and so on.

(/ )

Supplier Homepage Product ECG/Patient monitor/Fingertip Pulse Oximeter/Blood Glucose M Monitor Ysd18L Hot Sale Multi-Parameter Medical Equipment Patient Monitor

Ysd18L Hot Sale Multi-Parameter Medical Equipment Patient Monitor

Purchase Qty.:
(Pieces)
1-99 100+
FOB Unit Price: US $900 US $650
Purchase Qty. (Pieces) FOB Unit Price
1-99 US $900
100+ US $650
Get Latest Price
Port: Chengdu, China
Production Capacity: 10000units Per Year
Payment Terms: L/C, T/T, D/P, Western Union, Paypal, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: YSD18L
  • Type: Patient/Fetal/Maternal Monitor
  • Group: Middle-aged and Old
  • Medical Devices Reg./Record No.: 20142211159
  • Option: IBP, Etco2 and 2-IBP
  • Display: 15" LED
  • Warranty: 12 Months
  • Color: White
  • N.W: 3.5kg
  • Transport Package: Carton
  • Origin: Chengdu
  • Classification: Physiological Functions of Diagnosis and Monitoring Equipment
  • Certification: CE, SGS, FDA, EEC, MSDS, ISO13485
  • Medical Device Regulatory Type: Type 2
  • 6 Standard Parameters: ECG, Resp, NIBP, SpO2, 2-Temp, Pr/Hr
  • Certification.: Ce, ISO13485
  • Print-Speed Selectable: 1cm/Mincm/Mincm/Minmm/Sec
  • Measurement Range: 30~240bpm
  • Touch Screen: Optional
  • Trademark: YSD
  • Specification: 400mm*300mm*280mm
  • HS Code: 90181930
Product Description
Interface
Transducer socket

a). ECG
b). SPO2
c). NIBP 
d). IBP 1 / IBP 2
e). TEMP 1 TEMP 2 / Mainstream EtCO2 / AG (multi-gas)
f). Sidestream EtCO2 

LAN / Central monitor system interface

The LAN port is for connecting the monitor to a central monitor system network.  

Input device interface

This optional interface provides an USB ports to enable the monitor to be connected   to off-the-shelf input devices:
Mouse: any specified trackball or USB mouse may be used for navigation and data entry.
Computer keyboard: an USB computer keyboard can be used for data entry instead of the on-screen pop-up keyboard.
Remark: user has to restart the machine after plug and unplug the mouse / computer keyboard.]Knob (Standard) 

Features

Core

Newly advanced YSD18L main board with Linux OS, calculating speed is 4 times faster than traditional products
Support storage of 2160 hours trend table and graph review, 2 hours waveform review, 2000 groups NIBP review and 2000 alarm events review

Body

1. 15 inch high-brightness TFT LED
2. Support display 9~13 waveforms
3. Support 7 channel ECG waveform display simultaneously 
4. Optional HDMI output

Printer

Built-in high-speed 50mm thermal printer (Brand: SEIKO, Japan)  

Central System

Optional Build-in wireless network module, supporting wired or wireless connection to the central monitoring station.
Optional Support HL7 (Health Level Seven)

Alarm

Double high light alarm light bar.
Three-level acousto-optic alarm
Sensor-off alarm
Paper out alarm
Support alarm review
Support alarm pause 

Linux OS

Support operation with mouse and computer keyboard (option)
Multi-display mode to meet different clinical requirement, including standard interface, big font, OxyCRG, trend graph,
NIBP review and full leads ECG interface.
NIBP self-test mode: including overpressure test, static pressure test and air leakage test.
Generate ID automatically when register a new patient
Support medical history search by patient ID, name and mobile number
18 types of Arrhythmia analysis and real-time S-T segment analysis and pacemaker detection
Drug calculation and titration table
Support multi-language display
Support online software upgrading by net/USB

Related Product

IBP accessoriesRespironics EtCO2 moduleNellcor SpO2 moduleMasimo Spo2 module

Performance Specifications

Dimension and Weight
Dimension: 393mm*382mm*173mm
Weight: 4.5kg(excluding accessories)

Power Supply

Voltage: AC100~240V, 50/60HZ, Power≤60W

Display

15" color TFT LED 
Resolution: 1024*768 pixels

Battery (Pluggable)

Type: Rechargeable lithium battery 14.8V/2200mAh
Charge Cycle: ≥500 times
Working time: 2 hours (optional larger battery for 4-5 hours)

Recorder (Option)

Method: Thermal printer
Paper width: 50 mm (1.97 in)
Printing speed: 12.5/ 25/ 50 mm/s
Trace: Max. 3 tracks
Recording way: Real-time Recording, Review Printing, 
Periodic Recording, Alarm Recording

Alarm

Level: Low, medium and high
Indication: Auditory and visual
Alarm volume adjustable
Alarm pause time: 1min, 2min
Parameter alarm type: Latch/ Unlatch

Input Device

Touch screen (option)
Knob (Standard)
Keypad input (Standard)
Mouse/ Keyboard input (option)

System Output & Extensible Interface

Ethernet Network: 1 standard RJ45 socket
USB Port: 1
Video Output:  1 HDMI port (option)

Operating Environment

Temperature:  5 ~ 40 ºC
Humidity:  15% ~ 80% (non-condensing)
Atmosphere pressure:  86 KPa ~ 110 KPa

Transportation and Storage Environment

Temperature:  -20~50 ºC
Humidity:  10%~90%  (non-condensing)
Atmosphere pressure:  86 KPa ~ 110 KPa

Safety

IEC60601-1 Approved, CE marking according to MDD93/42/EEC
With reference to RoHS Directive 2011/65/EU recasting

Trend & Reviewing

Trend: 2160 hours
ARR events: 128 groups of ARR events and associated waveform
NIBP measurement reviewing: 2000 groups
Waveform review: 2 hours
Alarm event: 2000 groups of parameter alarms events and associated parameter

ECG

Lead mode: 3/5 Leads, I, II, III or I, II, III, AVR, AVL, AVF, V
Protection: Breakdown Voltage 4000VAC 50/60Hz; Defibrillator proof
Gain: 2.5mm/mV(×0.25), 5.0mm/mV(×0.5), 10mm/mV (×1), 20mm/mV (×2), 40 mm/ mV (×4), Auto
Sweep speed: 12.5 mm/s, 25 mm/s, 50 mm/s
ECG signal range:  ±12 mV (Gain × 0.25)
Accuracy: ±1bpm/ ±1%, whichever is greater
Resolution: 1 bpm
Leakage Current < 10 μA
Baseline Recovery: ≤ 3s after defibrillation (Monitor mode)≤ 1s after defibrillation (Surgery mode)
Bandwidth: Surgery 1 ~ 25 Hz
Monitor 0.5 ~ 40 Hz
Diagnostic 0.05 ~ 120 Hz
Indication of Electrode Separation: Every electrode (exclusive of RL)

Heart Rate

Measure range: Adult: 0bpm; 10 ~ 300 bpmNeo/Ped: 0bpm; 10 ~ 350 bpm
Resolution: 1 bpm
Accuracy: ± 1% or ± 1bpm, whichever is greater

ST Measurement

Range: -2.0 ~ +2.0 mV
Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, whichever is greater
Other range: unspecified
Resolution: 0.01mV

Respiration

Method: Impedance between RA-LL, RA-LA
Gain: ×0.25, ×0.50, ×1, ×2, ×4
Respiration Rate: 0bpm, 6 ~ 150 BrPM
Sweep speed:  6.25 mm/s, 12.5 mm/s, 25mm/s
Resolution: 1 BrPM
Accuracy: ±2 bpm or ±2%, whichever is greater
Apnea Alarm: 10 ~ 60 s

NIBP

Method: Oscillometric
Measure mode: Manual, Auto, STAT
Measure Interval in AUTO Mode 1~480 min
STAT mode cycle time: Keep 5 minutes, at 5 seconds interval
Measure and Alarm Range:
Adult:   SYS:  30 ~ 270 mmHg    Pediatric:   SYS:  40 ~ 235 mmHg DIA: 10 ~ 220 mmHg   MEAN:  20 ~ 225 mmHg
Neonate:  SYS:  30 ~ 135 mmHg DIA: 10 ~ 110 mmHg   MEAN:  20 ~ 125 mmHg Static pressure accuracy: ±3mmHg
Resolution: 1mmHg
Accuracy: Maximum Mean error ±5mmHg  Maximum Standard deviation ≤8mmHg
Over pressure Protection: Dual protection via software & hardware

Temperature

Technique: Thermistor probe (2.25K)
Channel:  Dual-channel, provide T1; T2; ΔT
Measuring and Alarm Range: 0.0 ºC~ 50 ºC (32ºF~ 122ºF)
Unit: Celsius (ºC), Fahrenheit ( ºF)
Resolution: 0.1ºCor 1ºF
Accuracy: ±0.1ºC(exclusive probe)

Performance Specifications

SpO2 (Digital Technic)

Measurement Range: 0 ~ 100 %
Resolution: 1 %
Accuracy:  ±2% (70% ~ 100%)  ±3 % (35% ~ 69%)  Unspecified (0 ~ 34%)
Support Pitch tone and multi-level volume  

Pulse Rate

Measuring and Alarm Range: 25~250bpm
Accuracy: ±1% or ±1 bpm, whichever is greater
Resolution: 1bpm

Nellcor-SpO2 (Option)

Measurement Range: 0 ~ 100 %
Resolution: 1 %
Accuracy:   70% ~ 100%, ±2 % (adult)          70% ~ 100%, ±3 % (Neonate)
            70% ~ 100%, ±2 % (Low Perfusion)  0% ~ 69%, unspecified

Pulse Rate

Measurement range: 20 ~ 300 bpm
Resolution: 1bpm
Accuracy: ±3 bpm (20 ~ 250 bpm)  unspecified (251~300 bpm)

Masimo SpO2 (Option)-

Measurement Range: 0 ~ 100 %-
Resolution: 1 %
Accuracy:  70% ~ 100%, ±2 % (adult/ pediatric, non-motion conditions)
           70% ~ 100%, ±3 % (neonate, non-motion conditions)
           70% ~ 100%, ±3 % (motion conditions)
           0% ~ 69% unspecified

Pulse Rate

Measurement range: 25 ~ 240 bpm
Resolution: 1bpm
Accuracy: ±3 bpm (non-motion condition)

EtCO2 (Mainstream/ Sidestream) (Option)

Measure method:  Non-dispersive infrared (NDIR)
Measure Range:  0 ~19.7% (0 ~ 150 mmHg)  0 ~ 20 kPa
Resolution: 0.1 mmHg
CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg41 ~ 70 mmHg, ±5% of reading71 ~ 100 mmHg, ±8% of reading101~ 150 mmHg,
±10% of reading at 760 mmHg, ambient temperature of 25ºC)
Respiratory Rate:  Range: 3 ~150 BrPM      Accuracy: ±1 bpm


EtCO2 (Micro-stream) (Option)

Measure method:  Non-dispersive infrared (NDIR)
Measure Range:  0 ~19.7% (0 ~150 mmHg) 0 ~ 20 kPa
Sample Rate: 50 mL/min ±10mL/min
Resolution:  0.1 mmHg (0 ~ 50 mmHg  )0.25 mmHg (50 ~ 114 mmHg)
CO2 Accuracy:  0 ~ 40 mmHg, ±2 mmHg 41 ~ 70 mmHg, ±5% of reading
71 ~ 100 mmHg, ±8% of reading 101~ 150 mmHg, ±10% of readingat 760 mmHg, ambient temperature of 35ºC)
Respiratory Rate: Range: 3 ~120 BrPM
Accuracy: ±1 bpm

Depth of Anesthesia (CSI) (Option)

EEG sensitivity:  ± 400μV
Noise: < 2μVp-p, < 0.4μV RMS, 1-250 Hz
CMRR: > 140 dB
Input impedance: > 50 Mohm
Sample rate: 2000 samples/sec, (14 bits equivalent)
BS%: 0-100, filter 1-42 Hz, 1 sec. display update
EMG: 0-100 Logarithmic. Filter 75-85 Hz, 1 sec. update
Alarms: High / Low with user selectable limit
Artifact rejection: Automatic
Sensor impedance range: 0-10 kOhm / measurement current 0.01 μA

Multi-gas/O2 (Anesthetic Gas) (Option)

Method: Infrared absorption
Gas sorts: CO2, N2O, Des, Iso, Enf, Sevo, Hal, O2 (Optional paramagnetic sensor)
Calibration: Room air calibration performed automatically when changing airway
Airway adapt (< 5 sec)
Measurement range: CO2: 0~25%,  N2O : 0~100%   O2: 0~100%,  Enf, Iso, Hal: 0~25%, Sevo, Des: 0~25%
Data output: Fi and ET values
Respiration rate: 0~ 150 BrPM
Other: Up to 5 waveforms displayed 
Agent mixture detection 
MAC value displayed

IBP (Option)

Max Channel: 2
Measurement way: Thermal resistance way
Press Sensor: Sensitivity   5 uV/V/mmHg, ±2%-
Impedance   300 to 3000Ω
Resolution: 1 mmHg
Unit: mmKg, kPa, cmH2O
Transducer sites: 
Arterial Pressure (ART)
Pulmonary Arterial (PA)
Left Arterial (LAP)
Right Arterial (RAP)
Central Venous Pressure (CVP)
Intracranial Pressure (ICP)
P1/ P2
Measuring and alarm range:
ART        0 ~ +350mmHgPA   -10 ~ +120 mmHgCVP/ RAP/ LAP/ ICP    -10 ~ +40 mmHg P1/ P2    -50 ~ +350mmHg
Accuracy:  Static: ±1mmHg or ±2%, whichever is greater (exclusive of transducer)±4mmHg or ±4%,
whichever is greater (inclusive of transducer)
Dynamic:  ±4mmHg or ±4%, whichever is greater

Model Configuration
 
Standard Config.15 inch LED, 3/5 Lead ECG, NIBP, SpO2, Pulse Rate, Temperature, Respiration
Optional Config.1/2 IBP, 2-Temperature, Nellcor SpO2, Masimo SpO2,
EtCO2 (Mainstream/Sidestream/Microstream),
Anesthesia Depth Monitoring (CSM module),
Multi-gas (AG) Monitoring
Optional Accessories:Touch Screen, Printer, USB Mouse/Computer Keyboard Input Function,
Central Monitoring Station,
Neo/Ped Accessories,
HDMI Output, Wall-mounting, Trolley,







 
Send your message to this supplier
Avatar
Mr. Justin
*From:
To: Mr. Justin
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now